summaryrefslogtreecommitdiffstats
path: root/Documentation
diff options
context:
space:
mode:
authorLinus Torvalds <torvalds@woody.linux-foundation.org>2007-01-22 08:57:03 -0800
committerLinus Torvalds <torvalds@woody.linux-foundation.org>2007-01-22 08:57:03 -0800
commit79d26287021d3158e3cb8da820f1b8233564dd3b (patch)
tree484d82e528c2e7326b26b3ed8910babe2b892595 /Documentation
parentc8fefb1bb4b38607d305c7e9ef55f146c9c628cb (diff)
parentc70a8c345fd770ecb2ff334bdf88b63edaffb77d (diff)
Merge branch 'hwmon-for-linus' of git://jdelvare.pck.nerim.net/jdelvare-2.6
* 'hwmon-for-linus' of git://jdelvare.pck.nerim.net/jdelvare-2.6: hwmon/w83793: Hide invalid VID readings hwmon/w83793: Fix the fan input detection hwmon/w83793: Ignore disabled temperature channels hwmon: Fix the VRD 11 decoding hwmon/w83793: Remove the description of AMDSI and update the voltage formula
Diffstat (limited to 'Documentation')
-rw-r--r--Documentation/hwmon/w837938
1 files changed, 2 insertions, 6 deletions
diff --git a/Documentation/hwmon/w83793 b/Documentation/hwmon/w83793
index 45e5408340e0..51171a83165b 100644
--- a/Documentation/hwmon/w83793
+++ b/Documentation/hwmon/w83793
@@ -45,18 +45,14 @@ This driver implements support for Winbond W83793G/W83793R chips.
temp5-6 have a 1 degree Celsiis resolution.
* Temperature sensor types
- Temp1-4 have 3 possible types. It can be read from (and written to)
+ Temp1-4 have 2 possible types. It can be read from (and written to)
temp[1-4]_type.
- - If the value of 0, the related temperature channel stops
- monitoring.
- If the value is 3, it starts monitoring using a remote termal diode
(default).
- - If the value is 5, it starts monitoring using the temperature sensor
- in AMD CPU and get result by AMDSI.
- If the value is 6, it starts monitoring using the temperature sensor
in Intel CPU and get result by PECI.
Temp5-6 can be connected to external thermistors (value of
- temp[5-6]_type is 4). They can also be disabled (value is 0).
+ temp[5-6]_type is 4).
* Alarm mechanism
For voltage sensors, an alarm triggers if the measured value is below